Summary for Test 2019-10-17-19-5
Test performed: CTM 643-June 2007Project Information
| Project Identifiers | Project ID: 214821 DEA: 120H1504 EFIS: 1216000055 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-1-4.9/5.5,10.5/14.1 |
| Award Date | 09/11/2020 |
| Closeout Date | 07/03/2024 |
| Work Description | Cold plane AC, RHMA-G paving, and curb ramp reconstruction |
| Location Description | ORANGE COUNTY IN LAGUNA BEACH AND NEWPORT BEACH FROM 0.2 MILE SOUTH OF VISTA DEL SOL TO 7TH AVENUE AND FROM LEDROIT STREET TO NEWPORT COAST DRIVE |
| QA Service Level | 1 (Verified on 10/26/2020) |
Sample Information
| Sample Taken Date | 10/17/2019 | Sample Unique Key | 19 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/29/2019 |
| Sample type | Preliminary | A brief description of the sample | SUBGRADE DEPTH 3'-4' |
| The quantity of what the sample constitutes | 1 BAG | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | JOSE | Last name of sampler or witnessed by | MENDEZ |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | 8780 | Linked DIME Sample ID | 2019-10-17-19 |
| The fabricator/manufacturer/facility name | Native Material | Transportation Laboratory (TL) Number | C936702 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | SR 01 PCH MB-32 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | AGURING |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-10-17-19
DIME Test ID: 2019-10-17-19-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-04-01
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: KIET PHAN
Date of test: 11/08/2019
Soil sample resistance (lab measure 1): 11000 Ohms
Soil sample resistance (lab measure 2): 7500 Ohms
Soil sample resistance (lab measure 3): 6200 Ohms
Soil sample resistance (lab measure 4): 6600 Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 6200 Ohms
Soil sample temperature: 20 C
Soil box constant: 1
pH of soil: 8.31
Minimum soil resistance corrected to 15.5: 6898 Ohms
Minimum soil resistivity at 15.5: 6898 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/1/2020 ✔