Summary for Test 2020-02-14-14-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 213733 DEA: 051C85U4 EFIS: 0518000156 |
|---|---|
| DIST-CO-RTE-PM | 05-SCR-1-10.2/17.5 |
| Award Date | 02/19/2019 |
| Closeout Date | 11/15/2021 |
| Work Description | Santa Cruz 1 CAPM and Bridge Rails |
| Location Description | SANTA CRUZ COUNTY IN AND NEAR SANTA CRUZ FROM NORTH APTOS UNDERPASS TO JUNCTION ROUTE 9. |
| QA Service Level | 1 (Verified on 02/14/2019) |
Sample Information
| Sample Taken Date | 02/14/2020 | Sample Unique Key | 14 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/04/2020 | Sample type | Verification |
| A brief description of the sample | Loose Mix HMA-A | The quantity of what the sample constitutes | One JMF |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Anthony |
| Last name of sampler or witnessed by | Romiza | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Salinas | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | Unknown |
| Sublot number | Unknown | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2020-02-14-14
DIME Test ID: 2020-02-14-14-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2020-03-20
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: E. Atkins
Date of test: 03/16/2020
Method Performed: no data
Mass of container filled with water: 7402 grams
Mass of oven-dry sample in air for Sample 1: 2624 grams
Mass of container filled with the sample and water for Sample 1: 8958 grams
Temperature of Water: 2147483647 °F
Specific Gravity for Sample 1: 2.455
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/20/2020 ✔