Summary for Test 2014-10-13-4-1
Test performed: ASTM C1064-08Project Information
| Project Identifiers | Project ID: 209175 DEA: 030F2204 EFIS: 0300000072 |
|---|---|
| DIST-CO-RTE-PM | 03-ED-50-R30.7/R31.7 |
| Award Date | 02/25/2014 |
| Closeout Date | 07/30/2015 |
| Work Description | REPLACE BRIDGE. |
| Location Description | SLY PARK UNDERCROSSING |
| QA Service Level | 1 (Verified on 11/01/2013) |
Sample Information
| Sample Taken Date | 10/13/2014 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/14/2014 |
| Sample type | Verification | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | 2 6x12 concrete cylinders | From where was the sample collected | Other |
| First name of sampler or witnessed by | Brandon | Last name of sampler or witnessed by | Miller |
| Title of sampler | Structure Representative | Telephone number of sampler | (916) 505-6839 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | 0 |
| The fabricator/manufacturer/facility name | Jobsite | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 25 0042 | |
| Structure name | Sly Park Rd UC | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SF850AFST0 |
|---|---|---|---|
| The truck number from where the sample was collected | 18 | The batch plant ticket number from where the sample was collected | 1051274 |
| Concrete batch plant | 1B | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow | Where the material sample would have been placed if not sampled | Not set |
| From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2014-10-13-4
DIME Test ID: 2014-10-13-4-1
Testing Lab: CT D03 - Sacramento Sanders Structures Construction Field Office
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2014-10-20
Test Results
Input Type: Measured
Tester's full name: Brandon Miller
Date of test: 10/13/2014
Temperature: 71 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/20/2014 ✔