Summary for Test 2020-03-06-17-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214140
DEA: 081J1104
EFIS: 0817000211
DIST-CO-RTE-PM08-RIV-10,79,86-Var
Award Date06/14/2019
Closeout Date06/23/2021
Work DescriptionREMOVE, PREPARE AND FURNISH POLYESTER CONCRETE OVERLAY.
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date03/06/2020 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing03/11/2020 Sample typeDepartment Acceptance
A brief description of the sample1/2 HMA-A-SP R15 Aggregate and RAP The quantity of what the sample constitutes2 boxes
From where was the sample collectedManufacturer First name of sampler or witnessed byKhoi
Last name of sampler or witnessed byVu Title of sampler
Telephone number of sampler Laboratory sample identification0170A-20
Linked DIME Sample ID The fabricator/manufacturer/facility nameCalifornia Commercial Asphalt - Coachella
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-03-06-17
DIME Test ID: 2020-03-06-17-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-03-16

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 03/12/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: no data F
Corrected Asphalt Binder Content: 5.42 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/16/2020 ✔