Summary for Test 2020-03-02-7-3

Test performed: CTM 211-May 2010

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/02/2020 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing03/02/2020 Sample typeAggregate Prequalification Program
A brief description of the sample3/8" Concrete Aggregate The quantity of what the sample constitutesproduction stockpile.
From where was the sample collectedManufacturer First name of sampler or witnessed byTrenton
Last name of sampler or witnessed byCrouse Title of samplerQC Supervisor
Telephone number of sampler(209) 834-8316 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Materials Vernalis
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0041::VERNALIS WEST & EAST PROPERTIES
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile Loader Blend
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-03-02-7
DIME Test ID: 2020-03-02-7-3
Testing Lab: Teichert Materials - Sacramento
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2020-03-16

Test Results


How many revolutions are required?: 500 Revolution Test
Input Type: Calculated
Tester's full name: Eric Gifford
Date of test: 03/05/2020
Grading: C
Percent wear: 26 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/16/2020