Summary for Test 2019-10-22-22-1

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214674
DEA: 120N7204
EFIS: 1214000093
DIST-CO-RTE-PM12-ORA-73-10.0/R28.0
Award Date09/16/2020
Closeout Date06/08/2026
Work DescriptionIN ORANGE COUNTY IN LAGUNA NIGUEL, LAGUNA BEACH, NEWPORT BEACH, ALISO VIEJO, LAGUNA HILLS, IRVINE AND COSTA MESA FROM 0.3 MI SOUTH OF NB 73/SB 5 CONNECTOR TO 0.2 MILE NORTH OF NB 73/NB 405 CONNECTOR.
Location DescriptionUPGRADE SAFETY DEVICES, RELOCATE CONTROL CABINET, CCTV'S & ELECTROLIERS, REMOVE & REPLACE OH SIGN STRUCTURES
QA Service Level1 (Verified on 10/27/2020)

Sample Information

Sample Taken Date10/22/2019 Sample Unique Key22
Date that the sample was received by the laboratory/organization performing the testing10/22/2019 Sample typePreliminary
A brief description of the sampleNATIVE SOIL BULK 0-5' DEPTH The quantity of what the sample constitutes1 bag
From where was the sample collectedJob Site First name of sampler or witnessed byLAIO
Last name of sampler or witnessed byQUANYAN Title of samplerTE CIVIL
Telephone number of sampler657-328-6593 Laboratory sample identification8783
Linked DIME Sample ID2019-10-22-22 The fabricator/manufacturer/facility nameNative Material
Transportation Laboratory (TL) NumberC17302-1 Inspector Lot Number from the Transportation Laboratory (TL) FormH-19-004
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedRTE 73 PM10 R28
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2019-10-22-22
DIME Test ID: 2019-10-22-22-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-03-16

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: KIET PHAN
Date of test: 11/10/2019
Soil sample resistance (lab measure 1): 7000 Ohms
Soil sample resistance (lab measure 2): 4700 Ohms
Soil sample resistance (lab measure 3): 5400 Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 4700 Ohms
Soil sample temperature: 23.3 C
Soil box constant: 1
pH of soil: 7.71
Minimum soil resistance corrected to 15.5: 5617 Ohms
Minimum soil resistivity at 15.5: 5617 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/16/2020 ✔