Summary for Test 2019-07-22-47-1
Test performed: CTM 643-June 2007Project Information
Project Identifiers | Project ID: 214698 DEA: 120N8904 EFIS: 1214000130 |
---|---|
DIST-CO-RTE-PM | 12-ORA-133-8.3/M9.3 |
Award Date | 11/09/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT AUXILIARY LANE. |
Location Description | ORANGE COUNTY IN IRVINE FROM ROUTE 133/405 SEPARATION TO IRVINE CENTER DRIVE OVERCROSSING |
QA Service Level | 1 (Verified on 02/22/2021) |
Sample Information
Sample Taken Date | 07/22/2019 | Sample Unique Key | 47 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/15/2019 |
Sample type | Preliminary | A brief description of the sample | NATIVE SOIL 0-60' DEPTH |
The quantity of what the sample constitutes | 1 BAG | From where was the sample collected | Job Site |
First name of sampler or witnessed by | BALA | Last name of sampler or witnessed by | KRISH |
Title of sampler | TE CIVIL | Telephone number of sampler | 657-328-6546 |
Laboratory sample identification | 8864 | Linked DIME Sample ID | 2019-07-22-47 |
The fabricator/manufacturer/facility name | NATIVE | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | A-19-003 BULK | Structure unique identifier | |
Structure name | RTE 133 PM 8 5 PM 9 3 |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | RTE 133 PM 8.5 -9.3 |
Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-07-22-47
DIME Test ID: 2019-07-22-47-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-03-13
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: TESS PEREZ
Date of test: 11/27/2019
Soil sample resistance (lab measure 1): 1700 Ohms
Soil sample resistance (lab measure 2): 700 Ohms
Soil sample resistance (lab measure 3): 700 Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 700 Ohms
Soil sample temperature: 22 C
Soil box constant: 1
pH of soil: 7.83
Minimum soil resistance corrected to 15.5: 814 Ohms
Minimum soil resistivity at 15.5: 814 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/13/2020 ✔