Summary for Test 2019-12-13-17-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 213976
DEA: 073W8804
EFIS: 0717000127
DIST-CO-RTE-PM07-LA-1-56.9/62.9
Award Date04/22/2019
Closeout Date11/02/2020
Work DescriptionAPPLY SLURRY SEAL AND REPLACE AC SURFACING.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM TRANCAS CANYON ROAD/BROAD BEACH ROAD TO THE VENTURA COUNTY LINE
QA Service Level1 (Verified on 11/02/2020)

Sample Information

Sample Taken Date12/13/2019 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing12/18/2019 Sample typeDepartment Acceptance
A brief description of the sampleAggregate Type III for Slurry Seal The quantity of what the sample constitutes1 Bags
From where was the sample collectedJob Site First name of sampler or witnessed bykevin
Last name of sampler or witnessed byHOPPKINS Title of samplerMREA
Telephone number of sampler Laboratory sample identification9036
Linked DIME Sample ID The fabricator/manufacturer/facility nameUnknown
Transportation Laboratory (TL) NumberC914681 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedSTOCKPILE @ JOBSITE
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-12-13-17
DIME Test ID: 2019-12-13-17-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-03-13

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: LARRY DIAZ
Date of test: 12/30/2019
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 6.9
Sand reading (test 1): 3.9
Clay reading (test 2): 6.9
Sand reading (test 2): 3.7
Clay reading (test 3): 6.9
Sand reading (test 3): 3.9
Sand equivalent (test 1): 57
Sand equivalent (test 2): 54
Sand equivalent (test 3): 57
Sand equivalent before temperature correction: 56
Sand equivalent after temperature correction: 56
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/13/2020 ✔