Summary for Test 2019-11-06-25-3
Test performed: CTM 643-June 2007Project Information
| Project Identifiers | Project ID: 214664 DEA: 081G7404 EFIS: 0816000060 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-R110.0 |
| Award Date | 12/01/2020 |
| Closeout Date | 06/30/2021 |
| Work Description | RECONSTRUCT EARTHEN DIKE, PLACE STRUC. STEEL BRIDGE & TORTOISE FENCE. |
| Location Description | BETWEEN BARSTOW AND BAKER AT 1.6 MILES SOUTH OF AFTON ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
| Sample Taken Date | 11/06/2019 | Sample Unique Key | 25 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/07/2019 | Sample type | Quality Assurance |
| A brief description of the sample | SOIL | The quantity of what the sample constitutes | 2 BAGS |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | HAKIMA |
| Last name of sampler or witnessed by | H | Title of sampler | TE CIVIL |
| Telephone number of sampler | 562-665-0454 | Laboratory sample identification | 8817 |
| Linked DIME Sample ID | 2019-11-06-25 | The fabricator/manufacturer/facility name | NATIVE |
| Transportation Laboratory (TL) Number | C639960 | Inspector Lot Number from the Transportation Laboratory (TL) Form | S-2 |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | 08-SBD-15-PM110 SURFACE |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-11-06-25
DIME Test ID: 2019-11-06-25-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-03-12
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: KIET PHAN
Date of test: 11/16/2019
Soil sample resistance (lab measure 1): 29000 Ohms
Soil sample resistance (lab measure 2): 17000 Ohms
Soil sample resistance (lab measure 3): 14000 Ohms
Soil sample resistance (lab measure 4): 14000 Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 14000 Ohms
Soil sample temperature: 22.2 C
Soil box constant: 1
pH of soil: 8.27
Minimum soil resistance corrected to 15.5: 16345 Ohms
Minimum soil resistivity at 15.5: 16345 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/12/2020 ✔