Summary for Test 2014-08-20-26-3
Test performed: CTM 211-May 2010Project Information
Project Identifiers | Project ID: 209242 DEA: 080P3104 EFIS: 0800001017 |
---|---|
DIST-CO-RTE-PM | 08-SBD-395-16.2 |
Award Date | 02/20/2014 |
Closeout Date | 06/19/2015 |
Work Description | INSTALL TRAFFIC SIGNAL, INTERCONNECT, RAMP METER, AND LIGHTING |
Location Description | SAN BERNARDINO COUNTY, IN ADELANTO, AT THE INTERSECTION OF STATE ROUTE 395 AND BARTLETT ROAD |
QA Service Level | 1 (Verified on 04/16/2014) |
Sample Information
Sample Taken Date | 08/20/2014 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/20/2014 |
Sample type | Annual Source Testing | A brief description of the sample | One inch PCC Aggregates |
The quantity of what the sample constitutes | 8 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Tom | Last name of sampler or witnessed by | Milum |
Title of sampler | QC Technician | Telephone number of sampler | Unknown |
Laboratory sample identification | 4237B | Linked DIME Sample ID | 0 |
The fabricator/manufacturer/facility name | Roberts Lucern Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | SMARA 91 36 0116 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Stockpiles |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2014-08-20-26
DIME Test ID: 2014-08-20-26-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2015-02-20
Test Results
How many revolutions are required?: 500 Revolution Test
Input Type: Calculated
Tester's full name: Nader Rashidi
Date of test: 08/26/2014
Grading: A
Percent wear: 42 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/20/2015 ✔