Summary for Test 2014-09-04-16-1

Test performed: ASTM C1064-08

Project Information

Project IdentifiersProject ID: 7780
DEA: 112T1824
EFIS: 1100020051
DIST-CO-RTE-PM11-SD-805-4.7/5.6
Award Date01/03/2013
Closeout Date09/07/2018
Work DescriptionREPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
QA Service Level1 (Verified on 12/10/2012)

Sample Information

Sample Taken Date09/04/2014 Sample Unique Key16
Date that the sample was received by the laboratory/organization performing the testing09/05/2014 Sample typeQuality Control
A brief description of the sampleconcrete The quantity of what the sample constitutesCylinders
From where was the sample collectedSource First name of sampler or witnessed byCharles
Last name of sampler or witnessed byLevinson Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample ID0 The fabricator/manufacturer/facility namesite
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierUnknown Structure nameRW 316 Sound Wall
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number103612F
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected128493
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTruck Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-09-04-16
DIME Test ID: 2014-09-04-16-1
Testing Lab: Vulcan Materials Company - San Diego
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2014-10-09

Test Results


Input Type: Calculated
Tester's full name: Charles Levinson
Date of test: 09/04/2014
Temperature: 72 F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/9/2014 ✔