Summary for Test 2020-02-08-1-8

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Award Date11/10/2017
Closeout Date01/14/2021
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
QA Service Level1 (Verified on 12/01/2017)

Sample Information

Sample Taken Date02/08/2020 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing02/10/2020 Sample typeVerification
A brief description of the sample1/2 HMA-A-SP R15 The quantity of what the sample constitutesPSUE 14 Bags
From where was the sample collectedManufacturer First name of sampler or witnessed byVulcan Oro Grande
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0126A-20
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Oro Grande
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Calmat, Lucerne Valley, Oro Grande
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R15 The fabricator/manufacturer designation for the sample324109 ORO SJR
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Vulcan Oro Grande Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-02-08-1
DIME Test ID: 2020-02-08-1-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2020-03-17

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 02/13/2020
Bulk dry specific gravity: 2.699
Average uncompacted voids: 47.9 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/17/2020 ✔