Summary for Test 2020-02-11-2-1

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 213489
Permit Numbers: 0817NMC1320 0819NRT0801 0819NRW0944 0819NRT0802 0819NRW0952 0819NRW1158 0819NRW1299 0820NRT0046 0820NRT0047
DIST-CO-RTE-PM08---27.05/27.55
Award Date06/01/2018
Closeout Date06/23/2021
Work DescriptionEnter onto Interstate 10 (I-10) right of way at Mountain View Avenue in the City of Redlands, to perform I-10 EB and WB off-ramps widening, install curb and gutter, ADA curb ramps, modify existing traffic signal, extend drainage box culvert, and install erosion control as per plans and specificatio
Location DescriptionI-10, EB and WB off-ramps, Loma Linda
QA Service Level1 (Verified on 08/13/2019)

Sample Information

Sample Taken Date02/11/2020 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing02/14/2020 Sample typeQuality Assurance
A brief description of the sample3/4"-10 x 15" x 3" The quantity of what the sample constitutes7
From where was the sample collectedManufacturer First name of sampler or witnessed byBrian
Last name of sampler or witnessed byMurray Title of sampler
Telephone number of sampler213 435 4055 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBlue Circle Corp
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL140-044-20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3093312 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationF1554 Grade 55
Bolt Length(s)15" x 3" Nut Specificationn/a
Washer Specificationn/a FinishHot Dipped Galvanized
Diameter/Size3/4" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2020-02-11-2
DIME Test ID: 2020-02-11-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-02-18

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 02/14/2020
UTM: 400kip
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11AUNC 3/4 0.33432377144968467072023620F1554 Full Length Tensile

General comments (publicly viewable) (Max 1000 characters): F1554 Full Length Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 2/18/2020 ✔