Summary for Test 2014-08-25-4-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout Date02/12/2025
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Sample Information

Sample Taken Date08/25/2014 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing09/16/2014 Sample typeVerification
A brief description of the sampleConcrete Samples The quantity of what the sample constitutes8 concrete cylinders
From where was the sample collectedOther First name of sampler or witnessed byPamela
Last name of sampler or witnessed byGagnier Title of samplerASR
Telephone number of sampler510-385-6960 Laboratory sample identification600002
Linked DIME Sample ID0 The fabricator/manufacturer/facility nameCentral Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberD1011C5E1
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedNA
Concrete batch plantNA The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedFrom the truck Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-08-25-4
DIME Test ID: 2014-08-25-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-10-06

Test Results


Unit system used?: US Units
Number of specimens: 4
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 10/06/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.99 in
Average diameter of cylinder 3: 5.99 in
Average diameter of cylinder 4: 5.98 in
Maximum load on cylinder 1: 160825 lb
Maximum load on cylinder 2: 177439 lb
Maximum load on cylinder 3: 179546 lb
Maximum load on cylinder 4: 163754 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Type of fracture pattern of cylinder 4: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Correction factor for cylinder 3: no data
Correction factor for cylinder 4: no data
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Cross sectional area of cylinder 3: 28.18 in^2
Cross sectional area of cylinder 4: 28.09 in^2
Compressive strength of cylinder 1: 5725.3 psi
Compressive strength of cylinder 2: 6296.6 psi
Compressive strength of cylinder 3: 6371.4 psi
Compressive strength of cylinder 4: 5829.6 psi
Compressive strength (to nearest 10 psi): 6060 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/6/2014 ✔