Summary for Test 2020-01-28-3-3
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 213411 DEA: 030H10U4 EFIS: 0317000246 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-5-9.7/24.9 |
| Award Date | 05/01/2019 |
| Closeout Date | 02/22/2024 |
| Work Description | Not set |
| Location Description | Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
| QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
| Sample Taken Date | 01/28/2020 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/30/2020 | Sample type | Department Acceptance |
| A brief description of the sample | #10 HRC 555 | The quantity of what the sample constitutes | 110 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Muser | Title of sampler | QA |
| Telephone number of sampler | 9165170532 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | PJ Rebar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-033-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4092790 | Head Manufacturer Lot Number(s) | 1 |
| Rebar Size | 10 | Headed Bar Model Name | 555 |
| Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
| Head Shape | Circular | Rebar Manufacturer | CMC Arizona |
| Head Manufacturer | HRC | Head Fabricator | HRC |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2020-01-28-3
DIME Test ID: 2020-01-28-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-02-03
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 02/03/2020
UTM: 400kip
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 1.27 | 121850 | 95945 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 2/3/2020 ✔