Summary for Test 2020-01-30-14-1
Test performed: CTM 643-June 2007Project Information
Project Identifiers | Project ID: 214653 DEA: 050K3304 EFIS: 0512000068 |
---|---|
DIST-CO-RTE-PM | 05-SB-101-45.5/45.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Gaviota Culvert Replacement |
Location Description | On Rte 101 in Santa Barbara County, near Gaviota State Park and just South of Gaviota Safety Roadside Rest Area |
QA Service Level | 1 (Verified on 01/30/2020) |
Sample Information
Sample Taken Date | 01/30/2020 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/30/2020 |
Sample type | Per Request | A brief description of the sample | Native Soil |
The quantity of what the sample constitutes | One Culvert | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Berven |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 20-D-007 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Existing | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | Unknown |
Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2020-01-30-14
DIME Test ID: 2020-01-30-14-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-01-31
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Measured
Tester's full name: Daniel Gingras
Date of test: 01/31/2020
Soil sample resistance (lab measure 1): 8800 Ohms
Soil sample resistance (lab measure 2): 3100 Ohms
Soil sample resistance (lab measure 3): 2100 Ohms
Soil sample resistance (lab measure 4): 2000 Ohms
Soil sample resistance (lab measure 5): 2200 Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 2000 Ohms
Soil sample temperature: 20.1 C
Soil box constant: 1
pH of soil: 7.25
Minimum soil resistance corrected to 15.5: 2230 Ohms
Minimum soil resistivity at 15.5: 2230 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/31/2020 ✔