Summary for Test 2020-01-01-7-1

Test performed: ASTM D445-14

Project Information

Project IdentifiersProject ID: 213943
DEA: 051G5704
EFIS: 0515000049
DIST-CO-RTE-PM05-SLO-58-0.7/1.9
Award Date06/14/2019
Closeout Date05/06/2020
Work DescriptionCOLD PLANE AC, PLACE RHMA-G AND RECONSTRUCT CURB RAMPS.
Location DescriptionSAN LUIS OBISPO COUNTY AT SANTA MARGARITA FROM 0.7 MILE EAST OF ROUTE 101/58 SEPARATION TO J STREET
QA Service Level1 (Verified on 08/20/2019)

Sample Information

Sample Taken Date01/01/2020 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testingNot set Sample typeQuality Control
A brief description of the sampleModifier The quantity of what the sample constitutes0
From where was the sample collectedManufacturer First name of sampler or witnessed byMr
Last name of sampler or witnessed bywitness Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTricor
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Modifier Asphalt Modifier Typeextender oil
Asphalt Modifier Mix NumberNot set

Test Details

DIME Sample ID: 2020-01-01-7
DIME Test ID: 2020-01-01-7-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: ASTM D445-14: Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) (Kinematic Viscosity)
Test Release Date: 2020-01-17

Test Results


Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 01/01/2020
First Kinematic Viscosity: 24 mm2/s
Second Kinematic Viscosity: 24 mm2/s
Kinematic Viscosity: 24 mm2/s
Dynamic Viscosity: 24 mPa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/17/2020 ✔