Summary for Test 2020-01-10-6-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210837
DEA: 080J0804
EFIS: 0800000283
COOP: 081625
DIST-CO-RTE-PM08-RIV-15-34.7/51.6
Award Date04/17/2017
Closeout Date08/01/2024
Work Description(Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location DescriptionRiverside County and SBD-15-0.0/1.3
QA Service Level1 (Verified on 05/08/2017)

Sample Information

Sample Taken Date01/10/2020 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing01/13/2020 Sample typeQuality Assurance
A brief description of the sample#5 Welded Hoops The quantity of what the sample constitutes38
From where was the sample collectedManufacturer First name of sampler or witnessed byFrederic
Last name of sampler or witnessed byAboujaoude Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Etiwanda
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4092624
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop4'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Etiwanda
Welding CompanyCMC Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2020-01-10-6
DIME Test ID: 2020-01-10-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-01-16

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 01/15/2020
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1215/16mm0.3131738.92102384Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 1/16/2020 ✔