Summary for Test 2019-12-11-21-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212794
DEA: 024F7804
EFIS: 0213000032
DIST-CO-RTE-PM02-SHA,LAS,PLU,SHA,SIS,TRI-5-22087-25.7
Award Date12/20/2018
Closeout Date10/20/2021
Work DescriptionCMS SIGNS IN SHASTA COUNTY
Location DescriptionIN BUTTE, LASSEN, PLUMAS, SHASTA, SISKIYOU AND TRINITY COUNTIES IN VARIOUS LOCATIONS.
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date12/11/2019 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing12/18/2019 Sample typeQuality Assurance
A brief description of the sample7/8-9 GR DH HV MG HEX NUT w/ blue dye The quantity of what the sample constitutes274
From where was the sample collectedFabricator First name of sampler or witnessed byJane
Last name of sampler or witnessed byLillard Title of samplerCALTRANS METS QA INSPECTOR
Telephone number of sampler916-308-9430 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameStructural and Steel Products
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormS52-031-19
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)DL18102872 Nut Mfg. Lot Number(s)409874A
Washer Mfg. Lot Number(s) Bolt Specificationn/a
Bolt Length(s)Unknown Nut SpecificationDH
Washer Specificationn/a Finishmechanically galvanized to ASTM B695
Diameter/Size7/8" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)not required. snug tight
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2019-12-11-21
DIME Test ID: 2019-12-11-21-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-12-23

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/20/2019
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A409874A81937Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 12/23/2019 ✔