Summary for Test 2019-12-11-14-3

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212794
DEA: 024F7804
EFIS: 0213000032
DIST-CO-RTE-PM02-SHA,LAS,PLU,SHA,SIS,TRI-5-22087-25.7
Award Date12/20/2018
Closeout Date10/20/2021
Work DescriptionCMS SIGNS IN SHASTA COUNTY
Location DescriptionIN BUTTE, LASSEN, PLUMAS, SHASTA, SISKIYOU AND TRINITY COUNTIES IN VARIOUS LOCATIONS.
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date12/11/2019 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/18/2019
Sample typeQuality Assurance A brief description of the sample3/4-10 GR DH HV MG NUT w/ blue dye
The quantity of what the sample constitutes462 From where was the sample collectedFabricator
First name of sampler or witnessed byJane Last name of sampler or witnessed byLillard
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler916-308-9430
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameStructural and Steel Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS52-031-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)100893710 Nut Mfg. Lot Number(s)414755A
Washer Mfg. Lot Number(s) Bolt Specificationn/a
Bolt Length(s)Unknown Nut Specificationn/a
Washer Specificationn/a FinishMechanically Galvanized to ASTM B695
Diameter/Size3/4" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)not required. snug tight

Test Details

DIME Sample ID: 2019-12-11-14
DIME Test ID: 2019-12-11-14-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-12-23

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/20/2019
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B414755A59442Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 12/23/2019