Summary for Test 2019-09-09-17-11

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214236
DEA: 024H3804
EFIS: 0218000112
MINOR: 02A1831
DIST-CO-RTE-PM02-PLU-36-6.6/6.6001
Award DateNot set
Closeout Date12/23/2020
Work DescriptionChester MS Infiltration Trench Project
Location DescriptionStorm Water Improvements in Plumas County about 1.9 miles West of Chester at the Chester Maintenance Station.
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date09/09/2019 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing09/10/2019 Sample typeVerification
A brief description of the sampleLaboratory-Combined Untreated Virgin 3/4-inch Type A Aggregate The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byRobert
Last name of sampler or witnessed byNixa Title of sampler
Telephone number of sampler Laboratory sample identificationD78166F
Linked DIME Sample ID The fabricator/manufacturer/facility nameSierra Cascade Aggregate and Asphalt Products
Transportation Laboratory (TL) Number847547 Inspector Lot Number from the Transportation Laboratory (TL) FormJMF
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-32-0002::CHESTER PIT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleL191072
The plant numberUnknown A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 19-28-S1b Lot number0
Sublot number0 Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-09-09-17
DIME Test ID: 2019-09-09-17-11
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-12-18

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 09/10/2019
Cumulative Percent Passing
%
100 %
100 %
99.3 %
73.5 %
59.7 %
46.9 %
38.3 %
23.9 %
16.4 %
12 %
8.9 %
6.4 %
4.74 %
General comments (publicly viewable) (Max 1000 characters): Lime treated cold feed grading, D78165, to make JMF tool function.

Test was verified on 12/18/2019 ✔