Summary for Test 2019-09-09-17-2
Test performed: CTM 204-June 2010Project Information
| Project Identifiers | Project ID: 214236 DEA: 024H3804 EFIS: 0218000112 MINOR: 02A1831 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-36-6.6/6.6001 |
| Award Date | Not set |
| Closeout Date | 12/23/2020 |
| Work Description | Chester MS Infiltration Trench Project |
| Location Description | Storm Water Improvements in Plumas County about 1.9 miles West of Chester at the Chester Maintenance Station. |
| QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
| Sample Taken Date | 09/09/2019 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/10/2019 |
| Sample type | Verification | A brief description of the sample | Laboratory-Combined Untreated Virgin 3/4-inch Type A Aggregate |
| The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Robert | Last name of sampler or witnessed by | Nixa |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D78166F | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Sierra Cascade Aggregate and Asphalt Products | Transportation Laboratory (TL) Number | 847547 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | JMF | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-32-0002::CHESTER PIT |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | L191072 |
| The plant number | Unknown | A detailed description of where the material sample was collected | Stockpiles |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | JMF 19-28-S1b | Lot number | 0 |
| Sublot number | 0 | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-09-09-17
DIME Test ID: 2019-09-09-17-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2019-12-18
Test Results
The test method used?: Plastic Index
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 10/02/2019
Liquid Limit (LL): 0 %
Plastic Limit (PL): 0 %
Plastic Index(PI): NP
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/18/2019 ✔