Summary for Test 2014-05-30-10007587-2

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 7780
DEA: 112T1824
EFIS: 1100020051
DIST-CO-RTE-PM11-SD-805-4.7/5.6
Award Date01/03/2013
Closeout Date09/07/2018
Work DescriptionREPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
QA Service Level1 (Verified on 12/10/2012)

Sample Information

Sample Taken Date05/30/2014 Sample Unique Key10007587
Date that the sample was received by the laboratory/organization performing the testingNot set Sample typeQuality Control
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes5 cylinders
From where was the sample collectedSource First name of sampler or witnessed byChristian
Last name of sampler or witnessed byWheeler Eng Title of sampler
Telephone number of sampler Laboratory sample identification2014-05-30-09-20-3079
Linked DIME Sample IDNot set The fabricator/manufacturer/facility nameVulcan Mission Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number103612F
The truck number from where the sample was collected222A The batch plant ticket number from where the sample was collected115597
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collected296L wall Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-05-30-10007587
DIME Test ID: 2014-05-30-10007587-2
Testing Lab: Vulcan Materials Company - San Diego
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-09-24

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Sara Thomspon
Date of test: 06/13/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Maximum load on cylinder 1: 81040 lb
Type of fracture pattern of cylinder 1: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 14 days
Compressive strength of cylinder (to nearest 10 psi): 2870 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/24/2014 ✔