Summary for Test 2019-12-12-10-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 3825
DEA: 07138204
EFIS: 0700000142
DIST-CO-RTE-PM07-LA-47,103-3.5/4.6,0.0/1.1
Award Date06/30/2011
Closeout Date07/14/2022
Work DescriptionREPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
QA Service Level1 (Verified on 03/29/2012)

Sample Information

Sample Taken Date12/12/2019 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/16/2019
Sample typeQuality Assurance A brief description of the sampleCoupon Casting
The quantity of what the sample constitutes2 From where was the sample collectedManufacturer
First name of sampler or witnessed byDebbie Last name of sampler or witnessed byOzuna
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDSI Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)K069
Part Number (s)68 19 172 Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)DSI
Prestressing ManufacturerFarrar

Test Details

DIME Sample ID: 2019-12-12-10
DIME Test ID: 2019-12-12-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2019-12-19

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: spaine
Date of test: 12/17/2019
UTM: 67kip
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1K0690.5030.19871637701064006.9spaine
2K0690.5030.19871642981128518.4spaine

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 12/19/2019