Summary for Test 2019-12-10-11-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213994 DEA: 040P7504 EFIS: 0417000517 |
---|---|
DIST-CO-RTE-PM | 04-SOL-12-7.5/13.6,20.5/25.0 |
Award Date | 04/29/2019 |
Closeout Date | 04/22/2020 |
Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE HMA (A). |
Location Description | SOLANO COUNTY NEAR SUISUN CITY FROM WALTERS ROAD TO SHILOH ROAD AND IN AND NEAR RIO VISTA FROM 0.2 MILE WEST OF CURRIE ROAD TO 0.2 MILE EAST OF CHURCH ROAD |
QA Service Level | 1 (Verified on 08/19/2019) |
Sample Information
Sample Taken Date | 12/10/2019 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/11/2019 |
Sample type | Per Request | A brief description of the sample | 3/4"HMA+RAP SP-WMA |
The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | Ignacio | Last name of sampler or witnessed by | Arechiga |
Title of sampler | Consultant | Telephone number of sampler | 209-480-0703 |
Laboratory sample identification | Con_19_806 | Linked DIME Sample ID | NA |
The fabricator/manufacturer/facility name | George Reed Plant | Transportation Laboratory (TL) Number | C882445 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | 03-Amador |
Structure name | NA |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 2 |
Sublot number | 3 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-12-10-11
DIME Test ID: 2019-12-10-11-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-12-16
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Zantino Ochoa
Date of test: 12/11/2019
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.78 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/16/2019 ✔