Summary for Test 2019-04-05-19-6
Test performed: CTM 204-June 2010Project Information
Project Identifiers | Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | 1 (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 04/05/2019 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/10/2019 |
Sample type | Verification | A brief description of the sample | Untreated 3/4" Virgin Aggregate |
The quantity of what the sample constitutes | Aggregate for JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Neale | Last name of sampler or witnessed by | B |
Title of sampler | NA | Telephone number of sampler | |
Laboratory sample identification | 19-J-003 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Granite, Arvin | Transportation Laboratory (TL) Number | C772606 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | |
Structure name | NA |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-15-0024::ARVIN PIT |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | HMA Plant Cold Feed |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-05-19
DIME Test ID: 2019-04-05-19-6
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2019-12-16
Test Results
The test method used?: Plastic Index
Input Type: Measured
Tester's full name: Clinton Edmiston
Date of test: 04/10/2019
Liquid Limit (LL): 0 %
Plastic Limit (PL): 0 %
Plastic Index(PI): NP
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/16/2019 ✔