Summary for Test 2019-12-04-10-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214329
DEA: 120S2404
EFIS: 1220000002
DIST-CO-RTE-PM12-ORA-91,90-6.42/6.5, 6.42
Award Date07/23/2019
Closeout Date06/08/2026
Work Descriptionrepair a damage steel girder by heat straightening as a result of a high load vehicle hit
Location DescriptionWestbound Route 91 at La Palma Avenue Bridge Structure at PM 6.42
QA Service Level1 (Verified on 08/15/2019)

Sample Information

Sample Taken Date12/04/2019 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing12/09/2019 Sample typeQuality Assurance
A brief description of the sample7/8"-9 x 3-1/2" F3125 The quantity of what the sample constitutes16
From where was the sample collectedOther First name of sampler or witnessed byKenneth
Last name of sampler or witnessed byVarela Title of samplerAssociate Steel Inspector
Telephone number of sampler(562) 440-7716 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUnytite Inc
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL08-067-19
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)28933-20578460
Heat Number(s)20578460 Nut Mfg. Lot Number(s)28526-75071352
Washer Mfg. Lot Number(s)D4913 Bolt SpecificationASTM F3125
Bolt Length(s)3-1/2 Nut SpecificationASTM A563 Gr. DH
Washer SpecificationASTM 436 FinishMG
Diameter/Size7/8"-9 Bolt Mfg. Lot Number28933-20578460
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2019-12-04-10
DIME Test ID: 2019-12-04-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-12-11

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/10/2019
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A28933-205784600.875071737319.110.00A325 Wedge Tensilespaine

General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 12/11/2019 ✔