Summary for Test 2019-10-25-22-3
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/25/2019 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/01/2019 |
Sample type | Verification | A brief description of the sample | RAP |
The quantity of what the sample constitutes | JMF Prequalification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cody | Last name of sampler or witnessed by | Brown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 19-263 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Syar Indunsties Lake Herman Batch | Transportation Laboratory (TL) Number | 911405 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Lake Herman Quarry |
---|---|---|---|
Aggregate Size | Unknown | Aggregate Source | Unknown |
RAP Stockpile | Static | Stockpile Size (tons) | 3200 |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2019-10-25-22
DIME Test ID: 2019-10-25-22-3
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-12-04
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Leif Ayres
Date of test: 12/04/2019
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.87 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/4/2019 ✔