Summary for Test 2019-04-01-47-1
Test performed: ASTM D217-16Project Information
| Project Identifiers | Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | 1 (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 04/01/2019 | Sample Unique Key | 47 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/01/2019 | Sample type | Verification |
| A brief description of the sample | Asphalt Rubber Binder, PG 64-16 CR | The quantity of what the sample constitutes | JMF Verification |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Barrett |
| Last name of sampler or witnessed by | Felder | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Griffith Edmonston | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | Not set | Lot number | Not set |
| Sublot number | Not set | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-01-47
DIME Test ID: 2019-04-01-47-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2019-12-03
Test Results
Determination: Block Penetration
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 07/01/2019
Block Penetration: 35 0.1 mm
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/3/2019 ✔