Summary for Test 2019-04-01-45-1
Test performed: ASTM D445-14Project Information
| Project Identifiers | Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | 1 (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 04/01/2019 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/01/2019 |
| Sample type | Verification | A brief description of the sample | Asphalt Modifier - Raffex 120 |
| The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Barrett | Last name of sampler or witnessed by | Felder |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | San Joaquin Refinery | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Modifier | Asphalt Modifier Type | Raffex 120 |
|---|---|---|---|
| Asphalt Modifier Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-01-45
DIME Test ID: 2019-04-01-45-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: ASTM D445-14: Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) (Kinematic Viscosity)
Test Release Date: 2019-12-03
Test Results
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 07/01/2019
First Kinematic Viscosity: 28 mm2/s
Second Kinematic Viscosity: 28 mm2/s
Kinematic Viscosity: 28 mm2/s
Dynamic Viscosity: 28 mPa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/3/2019 ✔