Summary for Test 2019-11-21-2-3
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212245 DEA: 024F8604 EFIS: 0213000043 |
---|---|
DIST-CO-RTE-PM | 02-TRI-36-26.7/27.1 |
Award Date | 11/02/2018 |
Closeout Date | 05/23/2022 |
Work Description | ROADWAY REALIGNMENT AND NEW BRIDGE CONSTRUCTION |
Location Description | TRINITY COUNTY ABOUT 9 MILES EAST OF FOREST GLEN FROM 0.6 MILE WEST TO 0.1 MILE WEST OF ROUTE 3 |
QA Service Level | 1 (Verified on 03/21/2017) |
Sample Information
Sample Taken Date | 11/21/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/25/2019 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A325 |
The quantity of what the sample constitutes | 120 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Charles | Last name of sampler or witnessed by | Franco |
Title of sampler | Telephone number of sampler | 858-583-9270 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 100794352 190518 B52967 | Nut Mfg. Lot Number(s) | 31113-S-190518 |
Washer Mfg. Lot Number(s) | 16447 | Bolt Specification | ASTM A325 |
Bolt Length(s) | 17.5" | Nut Specification | ASTM A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 19413 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-11-21-2
DIME Test ID: 2019-11-21-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-11-25
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 11/25/2019
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1C | 19413 | 0.8750 | 56519 | 251.41 | 10.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 11/25/2019 ✔