Summary for Test 2019-11-14-11-2

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 214167
DEA: 043Q0504
EFIS: 0419000141
DIST-CO-RTE-PM04-CC-4-24.9/27, 24.9/27.0
Award Date04/09/2019
Closeout Date03/04/2021
Work DescriptionInjection grouting and replace PCC slabs
Location DescriptionIn Pittsburgh and Antioch, from 0.1 mile west of Century Blvd to 0.1 mile east of Conta Loma Blvd
QA Service Level1 (Verified on 09/16/2019)

Sample Information

Sample Taken Date11/14/2019 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing11/15/2019 Sample typeQuality Assurance
A brief description of the sample6x12 concrete cylinders (2 total) The quantity of what the sample constitutesmix design ver-85-lv
From where was the sample collectedFabricator First name of sampler or witnessed byRyan
Last name of sampler or witnessed byCummings Title of samplerCT METS QA INSPECTOR
Telephone number of sampler209-662-3492 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameConFab Lathrop
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormS29-171-19
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberVER-85LV
The truck number from where the sample was collected3 The batch plant ticket number from where the sample was collected4879
Concrete batch plantonsite Conco The fabricator/manufacturer designation for the sampleConFab
A detailed description of where the material sample was collectedForm 2 Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2019-11-14-11
DIME Test ID: 2019-11-14-11-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-11-21

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: LMC
Date of test: 11/21/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.03 in
Maximum load on cylinder 1: 173481 lb
Maximum load on cylinder 2: 176830 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.35 in^2
Cross sectional area of cylinder 2: 28.54 in^2
Compressive strength of cylinder 1: 6119.3 psi
Compressive strength of cylinder 2: 6195.9 psi
Compressive strength (to nearest 10 psi): 6160 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 11/21/2019 ✔