Summary for Test 2014-08-25-3-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 7285 DEA: 040120T4 EFIS: 0400000027 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-12.6/13.9 |
Award Date | 11/27/2012 |
Closeout Date | Not set |
Work Description | CONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES |
Location Description | THE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL |
QA Service Level | 1 (Verified on 10/29/2012) |
Sample Information
Sample Taken Date | 08/25/2014 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/16/2014 |
Sample type | Verification | A brief description of the sample | Concrete Samples |
The quantity of what the sample constitutes | 8 concrete cylinders | From where was the sample collected | Other |
First name of sampler or witnessed by | Pamela | Last name of sampler or witnessed by | Gagnier |
Title of sampler | ASR | Telephone number of sampler | 510-385-6960 |
Laboratory sample identification | 600001-2 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Central Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | D1011C5E1 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | NA | |
Concrete batch plant | NA | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | From the truck | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2014-08-25-3
DIME Test ID: 2014-08-25-3-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-09-22
Test Results
Unit system used?: US Units
Number of specimens: 4
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 09/22/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Average diameter of cylinder 3: 5.98 in
Average diameter of cylinder 4: 5.99 in
Maximum load on cylinder 1: 154982 lb
Maximum load on cylinder 2: 171456 lb
Maximum load on cylinder 3: 171770 lb
Maximum load on cylinder 4: 171404 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Type of fracture pattern of cylinder 4: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Correction factor for cylinder 3: no data
Correction factor for cylinder 4: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Cross sectional area of cylinder 3: 28.09 in^2
Cross sectional area of cylinder 4: 28.18 in^2
Compressive strength of cylinder 1: 5517.3 psi
Compressive strength of cylinder 2: 6103.8 psi
Compressive strength of cylinder 3: 6115 psi
Compressive strength of cylinder 4: 6082.5 psi
Compressive strength (to nearest 10 psi): 5950 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/22/2014 ✔