Summary for Test 2019-10-31-1-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212687 DEA: 06442544 EFIS: 0612000175 |
---|---|
DIST-CO-RTE-PM | 06-KER-46,5-31.5-33.2 |
Award Date | 01/11/2018 |
Closeout Date | 11/19/2021 |
Work Description | CONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY. |
Location Description | KERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION |
QA Service Level | 1 (Verified on 03/12/2018) |
Sample Information
Sample Taken Date | 10/31/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/08/2019 |
Sample type | Quality Assurance | A brief description of the sample | 3/4"-10 x 29" ATR F1554-55 Plain |
The quantity of what the sample constitutes | 16 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA | Telephone number of sampler | 213 435 4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Industrial Bolt and Supply | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-047-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 58038747 | Nut Mfg. Lot Number(s) | 422614A |
Washer Mfg. Lot Number(s) | 218L036-132 | Bolt Specification | ASTM F1554-55 |
Bolt Length(s) | 29" | Nut Specification | ASTM 563 DH |
Washer Specification | ASTM F436-11 | Finish | Plain |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 02 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-10-31-1
DIME Test ID: 2019-10-31-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-11-13
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 11/12/2019
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 422614A | 59131 | Nut Proof Load | spaine |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 11/13/2019 ✔