Summary for Test 2019-10-28-24-3
Test performed: ASTM D2628-91-re11-highProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/28/2019 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/30/2019 |
Sample type | Quality Assurance | A brief description of the sample | 3.75 elastomeric joint seal |
The quantity of what the sample constitutes | 550ft | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Simon |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Watson Bowman | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 0519382 |
---|---|---|---|
Manufacturer(s) | Watson Bowman | Temperature | 72 |
Humidity | 50 | Comments | Unknown |
Joint Seal Size | 3.75 |
Test Details
DIME Sample ID: 2019-10-28-24
DIME Test ID: 2019-10-28-24-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2628-91-re11-high: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (High Temp Recovery)
Test Release Date: 2019-11-19
Test Results
Input Type: Measured
Tester's full name: Rheanna Andelin
Date of test: 11/04/2019
Temperature: 72 f
Humidity: 50 %
High Temp Recovery (70 hrs at 212F) Size Before (Height of Contact Face ): 3.75 in
High Temp Recovery (70 hrs at 212F) Size After (Expanded Contact Face ): 3.804 in
Percent Recovery (High Temp): 101 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/19/2019 ✔