Summary for Test 2019-10-14-5-9

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 213740
DEA: 07312604
DIST-CO-RTE-PM07-LA-5-R77.5/R81.8
Award Date01/04/2019
Closeout Date06/04/2020
Work DescriptionEXCAVATE DITCHES, PLACE PERM MTL, AND CONSTRUCT RET WALLS.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.4 MILE SOUTH OF SMOKEY BEAR ROAD UNDERCROSSING TO 0.3 MILE SOUTH OF ROUTE 5/138 SEPARATION
QA Service Level1 (Verified on 06/04/2020)

Sample Information

Sample Taken Date10/14/2019 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing10/15/2019 Sample typeVerification
A brief description of the sample3/4 WMA-A-SP R15 The quantity of what the sample constitutesPSUE 12 Bags
From where was the sample collectedManufacturer First name of sampler or witnessed byVulcan Sun Valley
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0631A-19
Linked DIME Sample ID The fabricator/manufacturer/facility nameSheldon, Boulevard, Big Rock Creek
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0017, 91-19-0019, 91-19-0021
The fabricator's/manufacturer's product name for the sample3/4 WMA-A-SP R15 The fabricator/manufacturer designation for the sample22086 - SVA SJR
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-10-14-5
DIME Test ID: 2019-10-14-5-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-05-07

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Husni Ankir
Date of test: 10/19/2019
Sieve SizeCumulative Percent Passing
100 %
100 %
100 %
100 %
100 %
100 %
100 %
97 %
76 %
59 %
46 %
34 %
24 %
16 %
10 %
General comments (publicly viewable) (Max 1000 characters): RAP Gradation After Ignition Oven

Test was verified on 5/7/2020 ✔