Summary for Test 2019-10-29-56-1
Test performed: ASTM D36-14ε1Project Information
| Project Identifiers | Project ID: 214136 DEA: 010F3604 EFIS: 0115000115 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-101-R39.2/R48.3 |
| Award Date | 07/31/2019 |
| Closeout Date | 01/04/2021 |
| Work Description | COLD PLANE AC PAVEMENT, RHMA OVERLAY, AND GUARDRAIL INSTALLATION. |
| Location Description | HUMBOLDT COUNTY NEAR REDCREST, PEPPERWOOD, AND STAFFORD FROM ENGLWOOD PARK UNDERCROSSING TO EEL RIVER BRIDGE AND OVERHEAD |
| QA Service Level | 1 (Verified on 06/24/2019) |
Sample Information
| Sample Taken Date | 10/29/2019 | Sample Unique Key | 56 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/29/2019 |
| Sample type | Quality Control | A brief description of the sample | 1/2" RHMA-G |
| The quantity of what the sample constitutes | JMF | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Matt | Last name of sampler or witnessed by | Horn |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Mercer Fraser B | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | San Joaquin Refining Co Inc |
|---|---|---|---|
| Performance Grade | Not set | Lot number | Not set |
| Sublot number | Not set | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2019-10-29-56
DIME Test ID: 2019-10-29-56-1
Testing Lab: Trinity Engineering Laboratories, Incorporated - Fresno
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2019-10-30
Test Results
ASTM Thermometer used?: F
Input Type: Calculated
Tester's full name: Matthew Horn
Date of test: 10/30/2019
Softening Point Sample 1: 69 F
Softening Point Sample 2: no data
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/30/2019 ✔