Summary for Test 2014-09-15-2-4
Test performed: ASTM C39-10
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Project Information
Project Identifiers | Project ID: 209059 DEA: 033E1004 EFIS: 0300000473 |
---|---|
DIST-CO-RTE-PM | 03-PLA-80-8.1/37.8 |
Award Date | 01/28/2014 |
Closeout Date | 01/23/2017 |
Work Description | IMPROVING VERTICAL CLEARANCE |
Location Description | PLACER COUNTY IN AND NEAR LOOMIS, PENRYN, NEWCASTLE, WEIMAR, AND MAGRA FROM 0.1 MILE WEST OF BRACE ROAD OVERCROSSING TO 0.1 MILE EAST OF MAGRA OVERCROSSING |
QA Service Level | 1 (Verified on 01/15/2014) |
Sample Information
Sample Taken Date | 09/15/2014 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/16/2014 |
Sample type | Quality Control | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | 8 concrete cylinders | From where was the sample collected | Other |
First name of sampler or witnessed by | j | Last name of sampler or witnessed by | harline |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | Not set | |
The fabricator/manufacturer/facility name | na | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | j7a8543cc |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | na | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | From the truck | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2014-09-15-2
DIME Test ID: 2014-09-15-2-4
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-09-18
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 09/18/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 115460 lb
Maximum load on cylinder 2: 114536 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 3 days
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 4056.9 psi
Compressive strength of cylinder 2: 4024.5 psi
Compressive strength (to nearest 10 psi): 4040 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/18/2014 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.