Summary for Test 2014-09-15-2-4

Test performed: ASTM C39-10
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 209059
DEA: 033E1004
EFIS: 0300000473
DIST-CO-RTE-PM03-PLA-80-8.1/37.8
Award Date01/28/2014
Closeout Date01/23/2017
Work DescriptionIMPROVING VERTICAL CLEARANCE
Location DescriptionPLACER COUNTY IN AND NEAR LOOMIS, PENRYN, NEWCASTLE, WEIMAR, AND MAGRA FROM 0.1 MILE WEST OF BRACE ROAD OVERCROSSING TO 0.1 MILE EAST OF MAGRA OVERCROSSING
QA Service Level1 (Verified on 01/15/2014)

Sample Information

Sample Taken Date09/15/2014 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/16/2014
Sample typeQuality Control A brief description of the sampleconcrete cylinders
The quantity of what the sample constitutes8 concrete cylinders From where was the sample collectedOther
First name of sampler or witnessed byj Last name of sampler or witnessed byharline
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample IDNot set
The fabricator/manufacturer/facility namena Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberj7a8543cc
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedna
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedFrom the truck Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-09-15-2
DIME Test ID: 2014-09-15-2-4
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-09-18

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 09/18/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 115460 lb
Maximum load on cylinder 2: 114536 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 3 days
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 4056.9 psi
Compressive strength of cylinder 2: 4024.5 psi
Compressive strength (to nearest 10 psi): 4040 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/18/2014

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.