Summary for Test 2019-09-27-26-7
Test performed: ASTM D4791-10Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/27/2019 | Sample Unique Key | 26 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
| Sample type | Quality Control | A brief description of the sample | 1/2 inch HMA-SP WMA PG 64-16 |
| The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Marina | Last name of sampler or witnessed by | Kamel |
| Title of sampler | Telephone number of sampler | 707-259-5708 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | SYAR Lake Herman Drum | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-48-0002::LAKE HERMAN QUARRY |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-09-27-26
DIME Test ID: 2019-09-27-26-7
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2019-10-29
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Marina Kamel
Date of test: 09/27/2019
Weighted percentage of particles (by mass) that were flat and elongated: 0.0 %
Weighted percentage of particles (by mass) that were not flat and elongated: 100 %
General comments (publicly viewable) (Max 1000 characters): Flat and elongated particles (by mass at 5:1) T4791
Test was verified on 10/29/2019 ✔