Summary for Test 2019-10-22-2-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 210569 DEA: 083555V4 EFIS: 0814000086 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-42.5/46.0 |
| Award Date | 11/05/2015 |
| Closeout Date | 01/18/2022 |
| Work Description | WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR. |
| Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
| Sample Taken Date | 10/22/2019 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/24/2019 | Sample type | Quality Assurance |
| A brief description of the sample | F3125 Grade F1852 1" x 2-3/4" Fastener | The quantity of what the sample constitutes | 12 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Arthur |
| Last name of sampler or witnessed by | Peterson | Title of sampler | QA Inspector |
| Telephone number of sampler | 707-342-8602 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Bristol Machine | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-149-19 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | Set No 30823 20632370 |
|---|---|---|---|
| Heat Number(s) | 20632370 6214953302 31915170 | Nut Mfg. Lot Number(s) | 30747-6214953302 |
| Washer Mfg. Lot Number(s) | D7678 | Bolt Specification | ASTM F3125 |
| Bolt Length(s) | 2-3/4" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | Plain |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 30823-20632370 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-10-22-2
DIME Test ID: 2019-10-22-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-10-29
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/28/2019
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 30747-6214953302 | 107096 | Nut Proof Load | spaine |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 10/29/2019 ✔