Summary for Test 2019-08-28-22-3
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 214437 DEA: 07323104 EFIS: 0716000061 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-210-R36.0/R40.6 |
| Award Date | 06/01/2022 |
| Closeout Date | 11/25/2024 |
| Work Description | PSR-TMDL |
| Location Description | LOS ANGELES COUNTY IN IRWINDALE AND AZUSA FROM 0.1 MILE EAST HIGHLAND AVENUE UNDERCROSSING TO SOUTH CITRUS AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 06/30/2021) |
Sample Information
| Sample Taken Date | 08/28/2019 | Sample Unique Key | 22 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/28/2019 |
| Sample type | Per Request | A brief description of the sample | Native Soil |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Kristopher | Last name of sampler or witnessed by | Barker |
| Title of sampler | Engineering Geologist | Telephone number of sampler | 909-806-4701 |
| Laboratory sample identification | 8701 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | K-32310-1 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | Shoulder of I-210, PM 36.0-40.6, BMP Location 161 |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-08-28-22
DIME Test ID: 2019-08-28-22-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-10-23
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Kiet Phan
Date of test: 08/29/2019
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 88 % | ||||||
| 84 % | ||||||
| 78 % | ||||||
| 73 % | ||||||
| 67 % | ||||||
| 64 % | ||||||
| 58 % | ||||||
| 55 % | ||||||
| 47 % | ||||||
| 42 % | ||||||
| 35 % | ||||||
| 27 % | ||||||
| 18 % | ||||||
| 11 % | ||||||
| 7.6 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/23/2019 ✔