Summary for Test 2019-10-14-7-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 213762
DEA: 032F3404
EFIS: 0300020616
DIST-CO-RTE-PM03-PLA-49-3.1/7.5
Award Date02/28/2019
Closeout Date05/11/2022
Work DescriptionWIDEN SHOULDERS, ADD RETAINING WALLS, REPLACE MBGR, CURBS & ELECTRICAL
Location DescriptionPLACER COUNTY IN AND NEAR AUBURN FROM 0.1 MILE SOUTH OF ROUTE 49/80 SEPARATION TO 0.1 MILE NORTH OF DRY CREEK ROAD
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date10/14/2019 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/16/2019
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutestwo From where was the sample collectedJob Site
First name of sampler or witnessed byM Last name of sampler or witnessed byAbbott
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namejobsite Transportation Laboratory (TL) Number204509
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number0000000000
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected00000000000
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedjobsite Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2019-10-14-7
DIME Test ID: 2019-10-14-7-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-10-21

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: JK
Date of test: 10/21/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 79766 lb
Maximum load on cylinder 2: 81629 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.35 in^2
Cross sectional area of cylinder 2: 28.26 in^2
Compressive strength of cylinder 1: 2813.6 psi
Compressive strength of cylinder 2: 2888.5 psi
Compressive strength (to nearest 10 psi): 2850 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 10/21/2019