Summary for Test 2019-10-14-3-7

Test performed: ASTM C191-13

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/14/2019 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing10/14/2019 Sample typeAnnual Source Testing
A brief description of the sampleType IL Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of sampler
Telephone number of sampler Laboratory sample identificationCM193901
Linked DIME Sample ID The fabricator/manufacturer/facility nameLaFarge
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandLaFarge
MillExshaw Type IL Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2019-10-14-3
DIME Test ID: 2019-10-14-3-7
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2021-01-08

Test Results


Input Type: Measured
Tester's full name: Stephen Donnelly
Date of test: 10/18/2019
Type of Water Used: Type IV grade reagent water
Time in minutes of last penetration greater than 25mm (E): 134 min
Time in minutes of first penetration less than 25mm (H): 135 min
Penetration reading at time E : 26 mm
Penetration reading at time H: 25 mm
Initial time of setting: 135 min
Final time of setting: no data
Method Used: Test Method A
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/8/2021