Summary for Test 2019-09-17-24-8
Test performed: CTM 205-December 2010Project Information
Project Identifiers | Project ID: 214000 DEA: 073W8604 EFIS: 0717000117 |
---|---|
DIST-CO-RTE-PM | 07-LA-1-35.3/46.9 |
Award Date | 05/01/2019 |
Closeout Date | 06/05/2020 |
Work Description | APPLY SLURRY SEAL TO ROADWAY. |
Location Description | LOS ANGELES COUNTY IN SANTA MONICA AND MALIBU FROM 0.3 MILE SOUTH OF PALISADE PEDESTRIAN OVERCROSSING TO MALIBU LAGOON BRIDGE |
QA Service Level | 1 (Verified on 07/26/2019) |
Sample Information
Sample Taken Date | 09/17/2019 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/19/2019 |
Sample type | Per Request | A brief description of the sample | Type 3 Slurry Seal/Micro-surfacing |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Hopkins |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | 8719 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | United Rock-Irwindale | Transportation Laboratory (TL) Number | C914200 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile at staging yard |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-09-17-24
DIME Test ID: 2019-09-17-24-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 205-December 2010: Method of Test for Determining Percentage of Crushed Particles
Test Release Date: 2019-10-09
Test Results
Will you be using 1/4 in. x No. 4 sieve?: No
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 09/26/2019
Percent Coarse Crushed: 100 %
Percent Fine Crushed: 100 %
General comments (publicly viewable) (Max 1000 characters):