Summary for Test 2019-09-19-10-5
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 09/19/2019 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/20/2019 |
Sample type | Verification | A brief description of the sample | 3/4" Aggregate for a RHMA-G JMF |
The quantity of what the sample constitutes | JMF Prequalification Program | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Rahshaun | Last name of sampler or witnessed by | Spears |
Title of sampler | Transportation Engineer | Telephone number of sampler | (916) 227-0384 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Syar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-48-0002::LAKE HERMAN QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | From the plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-09-19-10
DIME Test ID: 2019-09-19-10-5
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2019-10-01
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 10/01/2019
Mass of measure: 187.8 grams
Bulk dry specific gravity: 2.549
Mass of sample and measure #1: 328.2 grams
Mass of sample and measure #2: 329.5 grams
Volume of cylinder: 100.1 mL
Mass of sample #1: 140.4 grams
Mass of sample #2: 141.7 grams
Uncompacted voids #1: 45 %
Uncompacted voids #2: 44.5 %
Average uncompacted voids: 44.8 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/1/2019 ✔