Summary for Test 2019-09-14-1-7

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 212011
DEA: 07252624
EFIS: 0700021272
DIST-CO-RTE-PM07-LA-5-R45.4/R61.2
Award Date04/17/2017
Closeout Date01/25/2021
Work DescriptionREHABILITATE CONCRETE PAVEMENT.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES AND AT CASTAIC FROM 0.2 MILE SOUTH OF ROUTE 14/5 SEPARATION TO 0.7 MILE NORTH OF PALOMAS WASH BRIDGE
QA Service Level1 (Verified on 05/03/2017)

Sample Information

Sample Taken Date09/14/2019 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing09/18/2019 Sample typeVerification
A brief description of the sample3/4 RHMA-G-SP The quantity of what the sample constitutesPSUE 5 Bags
From where was the sample collectedManufacturer First name of sampler or witnessed byAlex
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0540G-19
Linked DIME Sample ID The fabricator/manufacturer/facility nameAll American Asphalt Corona
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample106835
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at All American Irwindale Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-09-14-1
DIME Test ID: 2019-09-14-1-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2019-10-07

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 09/21/2019
Weighted percentage of particles (by mass) that were flat and elongated: 2 %
Weighted percentage of particles (by mass) that were not flat and elongated: 98 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/7/2019 ✔