Summary for Test 2019-08-07-29-3

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214439
DEA: 120R9404
EFIS: 1219000063
MINOR: 12A1823
DIST-CO-RTE-PM12-ORA-1-27
Award DateNot set
Closeout Date07/02/2024
Work DescriptionREPLACE AGING AND DETERIORATED TRAFFIC SIGNAL POLES AT SR1 AND SEAPOINT STREET IN THE CITY OF HUNTINGTON BEACH, ORANGE COUNTY
Location DescriptionNot set
QA Service Level1 (Verified on 09/02/2020)

Sample Information

Sample Taken Date08/07/2019 Sample Unique Key29
Date that the sample was received by the laboratory/organization performing the testing08/21/2019 Sample typePer Request
A brief description of the sampleSoil The quantity of what the sample constitutes1 bag
From where was the sample collectedJob Site First name of sampler or witnessed byKristopher
Last name of sampler or witnessed byBarker Title of samplerEngineering Geologist
Telephone number of sampler654-328-6593 Laboratory sample identification8696
Linked DIME Sample ID The fabricator/manufacturer/facility nameCaltrans
Transportation Laboratory (TL) NumberD-16200-1 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedBoring No. R-19-001
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2019-08-07-29
DIME Test ID: 2019-08-07-29-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-09-24

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Tess Perez
Date of test: 08/27/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 795 Ohms
Soil sample temperature: 21.6 C
Soil box constant: 1
pH of soil: 9.10
Minimum soil resistance corrected to 15.5: 916 Ohms
Minimum soil resistivity at 15.5: 916 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): Since R minimum was less than 1100 ohms-cm, sample was shipped to TransLab for determination of Sulfate/Chloride contents.

Test was verified on 9/24/2019 ✔