Summary for Test 2019-09-16-10-1

Test performed: ASTM A931-0810

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/16/2019 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing09/17/2019 Sample typeQuality Assurance
A brief description of the sampleWire Rope The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byShawn
Last name of sampler or witnessed bySilva Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCaltrans
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM10 - Wire Rope Choker Reel Number2
Painter Name or ID103070 Material SpecificationASTM A931
Size5/16 in Wire ManufacturerUnknown
Material Collected to TestOperator

Test Details

DIME Sample ID: 2019-09-16-10
DIME Test ID: 2019-09-16-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Test Release Date: 2019-09-20

Test Results


Input Type: Measured
Tester's full name: She Vang
Date of test: 09/20/2019
Temperature: 72 f
UTM: 67KIP
Specimen Identification: 1
Peak Load: 11482.5 lbf
Operator: bewing
Location of Failure: at crimp
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/20/2019