Summary for Test 2019-09-10-16-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214002
DEA: 074W1204
EFIS: 0718000029
DIST-CO-RTE-PM07-VEN-23,33,101-Varies
Award Date05/07/2019
Closeout Date01/25/2021
Work DescriptionSEAL DECK, PLACE POLYESTER CONCRETE OVERLAY & REPLACE APPROACH SLAB.
Location DescriptionVENTURA COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 06/18/2019)

Sample Information

Sample Taken Date09/10/2019 Sample Unique Key16
Date that the sample was received by the laboratory/organization performing the testing09/13/2019 Sample typeVerification
A brief description of the sample1/2 HMA-A-SP R15 The quantity of what the sample constitutesPSE 8 bags
From where was the sample collectedManufacturer First name of sampler or witnessed byKevin
Last name of sampler or witnessed byHopkins Title of sampler
Telephone number of sampler Laboratory sample identification0529A-19
Linked DIME Sample ID The fabricator/manufacturer/facility nameGriffith Lebec
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-15-0068::GRIFFITH COMPANY
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R15 The fabricator/manufacturer designation for the sampleGRF-19-G3-05
The plant numberUnknown A detailed description of where the material sample was collectedBelty Cut at Griffith Edmonston Lebec
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-09-10-16
DIME Test ID: 2019-09-10-16-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-10-07

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Edmond Jabbour, Satish Jain
Date of test: 09/17/2019
Cumulative Percent Passing
%
100 %
100 %
100 %
96 %
82 %
82 %
54 %
38 %
27 %
20 %
14 %
8 %
4.8 %
General comments (publicly viewable) (Max 1000 characters): Lime Treated Aggregate

Test was verified on 10/7/2019 ✔