Summary for Test 2019-09-11-19-2
Test performed: ASTM F606-14Project Information
| Project Identifiers | Project ID: 212687 DEA: 06442544 EFIS: 0612000175 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-46,5-31.5-33.2 |
| Award Date | 01/11/2018 |
| Closeout Date | 11/19/2021 |
| Work Description | CONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY. |
| Location Description | KERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION |
| QA Service Level | 1 (Verified on 03/12/2018) |
Sample Information
| Sample Taken Date | 09/11/2019 | Sample Unique Key | 19 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/16/2019 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Rod | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Angelica |
| Last name of sampler or witnessed by | Zarate | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Gerdau | |
| Transportation Laboratory (TL) Number | NA | Inspector Lot Number from the Transportation Laboratory (TL) Form | NA |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 58037789 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Gr 55 | |
| Bolt Length(s) | 29 | Nut Specification | NA |
| Washer Specification | NA | Finish | |
| Diameter/Size | .75 | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-09-11-19
DIME Test ID: 2019-09-11-19-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2019-09-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: BE
Date of test: 09/20/2019
UTM: 400KIP
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 3/4 | 0.334 | 30766 | 136 | 92113 | 73128 | 24425 | F1554 Rod |
General comments (publicly viewable) (Max 1000 characters): F1554 Rod
Test Graph
Source: Bluehill Data Point FileTest was verified on 9/20/2019 ✔